1.1
|
“Background Technology” of a Party means all Intellectual Property that (a) is (i) owned or licensed by such Party and (ii) is in existence in electronic or written form on or prior to the effective date or (b) is developed, acquired, or licensed by such Party after the effective date and relates to the Business of NMHG or Flux ESS respectively.
|
1.2
|
The “Business of NMHG” shall mean the business of designing, engineering, manufacturing and selling materials handling equipment and components thereof, including but not limited to lift trucks, warehouse lift trucks, counterbalanced lift trucks and large capacity cargo and container handling lift trucks.
|
1.3
|
“NMHG Products” means the materials handling equipment and components thereof (including a battery charger, Software Interface and not including Flux ESS or Flux’s Background Technology), and further including but not limited to lift trucks, warehouse lift trucks, counterbalanced lift trucks and large capacity cargo and container handling lift trucks.
|
1.4
|
“Battery Pack Design” means the specific external package design specified in the Deliverables for the use in NMHG Products or related interconnects between Flux’s ESS and NMHG’s Products to the extent they are developed under this Agreement but does not include the Intellectual Property, technology or design of Flux’s ESS or Flux’s Background Technology.
|
1.5
|
“Deliverables” means any physical deliverables specifically purchased by NMHG in an applicable Schedule, Battery Pack Design and Software Interface that Flux will deliver to NMHG during or at the completion of the performance of each Schedule. Deliverables shall be provided to NMHG in accordance with each Schedule and shall conform to the specifications set forth therein;
|
1.6
|
“Flux ESS” means Flux’s energy storage systems, technology, know-how and related Intellectual Property and solutions to power vehicles, prototypes, products and solutions including but not limited to lithium-ion battery cells, battery balancing boards, battery control module, battery interconnects, power distribution unit, DC/DC converter, software, firmware, enclosures and any additional products directly related to Flux’s Background Technology and specifically does not include NMHG’s Background Technology;
|
1.7
|
“Intellectual Property” means all algorithms, apparatus, circuit designs and assemblies, databases and data collections, designs, diagrams, documentation, drawings, flow charts, formulae, ideas and inventions (whether or not patentable or reduced to practice), know-how, materials, marketing and development plans, marks (including brand names, product names, logos, and slogans), methods, models, network configurations and architectures, procedures, processes, protocols, schematics, software code (in any form including source code and executable or object code), specifications, subroutines, techniques, tools, uniform resource identifiers, user interfaces, web sites, works of authorship, and other forms of technology and intellectual property.
|
1.8
|
“Intellectual Property Rights” means worldwide common law and statutory rights associated with (i) patents and patent applications; (ii) works of authorship, including mask work rights, copyrights, copyright applications, copyright registrations and "moral" rights; (iii) the protection of trade and industrial secrets and confidential information; (iv) other proprietary rights relating to intangible intellectual property (specifically including trademarks, trade names and service marks); (v) analogous rights to those set forth above; and (vi) divisions, continuations, renewals, reissuances and extensions of the foregoing (as applicable) now existing or hereafter filed, issued or acquired.
|
1.9
|
“PCR” means a mutual written agreement by Parties’ management of a change of Deliverables using Flux’s project change request form.
|
1.12
|
“Software Interface” means the software program that specifically developed under this Agreement that provides a logical interface and communication between Flux’s ESS and NMHG’s Control Unit and does not mean any, hardware, software or firmware of Flux’s ESS or Background Technology.
|
2.1
|
Flux agrees to provide Deliverables for NMHG pursuant to the terms and conditions set forth in this Agreement and each fully executed Schedule that references this Agreement. At a minimum, Schedules shall include details of the Deliverables, estimated dates the Deliverables should be made available and estimated costs to NMHG of providing such Deliverables.
|
2.2
|
Flux agrees to use best efforts to provide the Deliverables associated in each Schedule. Unless agreed upon in a Schedule Flux shall not be penalized for late Deliverables. In the event Deliverables are not met or in the event Deliverables are late the Parties agree to negotiate a cure period in good faith.
|
2.3
|
When applicable NMHG shall use best efforts to assist Flux in providing Deliverables, which may include but is not limited to access to NMHG’s facilities, personnel, and NMHG Products.
|
2.4
|
Parties agree that due to various reasons and often outside of the control of Parties the scope, types and schedule of the Deliverables may change. Changes requested by NMHG shall be made using PCR and are subject to additional fees and costs.
|
3.1
|
Upon pre-approval, which shall not be unreasonably denied, NMHG agrees to reimburse Flux for any out-of-pocket expenses incurred in the event travel is required.
|
3.2
|
NMHG shall pay Flux the fees set forth in an applicable Schedule in accordance with the Schedule’s payment terms therein. In the case of fees due not specifically identified in an applicable Schedule (i.e. travel expenses) Flux shall provide a true and correct invoice to NMHG and NMHG agrees that all fees shall be paid within thirty (30) days from the date of such invoice.
|
4.1
|
Each Party shall have and retain exclusive ownership of its Background Technology, including any Intellectual Property Rights therein. All Intellectual Property discovered, created or developed under, or in connection with, this Agreement that directly relates to Flux’s ESS and Flux’s Background Technology shall be and remain the sole property of Flux and its assigns. All Intellectual Property discovered, created or developed under, or in connection with, this Agreement that directly relates to NMHG Background Technology or the NMHG Products shall be and remain the sole property of NMHG and its assigns. To the extent that the Deliverables include a Software Interface and a Battery Pack Design, Flux hereby grants to NMHG the irrevocable, perpetual, fully paid, non-exclusive, worldwide, right and license to use, execute, sell, reproduce, display, perform, distribute copies of, and prepare derivative works of the Software Interface and Battery Pack Design.
|
4.2
|
Except as provided in this Agreement, neither party may use, reproduce, distribute or disclose Confidential Information it receives from the other party under this Agreement, without the prior written authorization of the disclosing party. Each party must hold in confidence Confidential Information received from the other party and must protect the confidentiality thereof with the same degree of care that it exercises with respect to its own information of like importance, but in no event less than reasonable care, for a period of (2) years from the date of receipt of the Confidential Information). “Confidential Information” shall mean information which if disclosed (i) in tangible form, is clearly marked as "confidential" or "proprietary" at the time of disclosure, or (ii) in intangible form (such as orally or visually), the disclosing party identifies as "confidential" or "proprietary" at the time of disclosure to the receiving party within thirty (30) days of disclosure. Notwithstanding the foregoing marking requirements, the parties agree that technical information regarding prototypes, Flux’s ESS and either party’s Background Technology shall always be deemed and considered Confidential Information.
|
4.3
|
During the term of this Agreement and for a period of two (2) years thereafter, neither party shall without the prior written consent of the other party, directly solicit any of the other party’s employees for employment; provided, however, that the foregoing restriction shall not apply to a general solicitation for application for employment made through advertising, web sites or other mediums not involving the direct targeted solicitation of a specific person.
|
5.1
|
Either party may terminate this Agreement and/or related Schedule for convenience with a sixty (60) day written notice. In the event of termination Flux shall use reasonable efforts to scale down any work on this Agreement or related Schedule and provide an itemized invoice of all work performed and expenses incurred up to the date of termination and NMHG agrees to pay said invoice within thirty (30) days.
|
5.2
|
With respect to disputes, the parties agree that in the event of any dispute or difference arising out of or relating to this Agreement, except for breach in NMHG’s lack of payment, the parties hereto shall use their best endeavors to settle such disputes or differences. To this effect, they shall consult and negotiate with each other, in good faith and understanding of their mutual interest, to reach a just and equitable solution within a period of thirty (30) days, and then the disputes or differences shall be finally settled by arbitration administered by the American Arbitration Association. This Agreement and all matters arising thereunder shall be governed by the laws of the state of California applicable therein without giving effect to the rules respecting conflict of law.
|
5.3
|
A party is not liable under this Agreement for non-performance caused by events or conditions beyond that party's control, if the party makes reasonable efforts to perform.
|
5.4
|
LIMITATION OF LIABILITY
|
5.5
|
Flux may assign or delegate portions or the entirety of the Deliverables to 3rd parties, subcontractors, contract manufacturers and consultants.
|
5.6
|
Except for agreements relating to confidentiality, this Agreement constitutes the entire agreement between NMGH and Flux with respect to the subject matter hereof and shall bind Parties and their perspective parents, subsidiaries and affiliates. Furthermore this Agreement supersedes all prior agreements, understandings and proposals, whether written or oral. This Agreement may not be amended or modified except by a writing signed by both parties. No oral statement of any person will, in any manner or degree, modify or otherwise effect the terms and provisions of this Agreement. Except for terms relating to Intellectual Property Rights, the terms and conditions of a related Schedule shall control if and when there is a conflict with any of the terms or conditions of this Agreement.
|
Flux Power, Inc.
|
NACCO Materials Handling Group, Inc.
|
By: /s/ Craig Miller
|
By: /s/ Rajiv K. Prasad
|
Name: Craig Miller
|
Name:Rajiv K. Prasa
|
Title: VP, Director of Legal Affairs
|
Title:VP Global Product Development
|
Date: 2-20-2012
|
Date: Feb 22, 2012
|
Introduction
|
Purpose and Scope
|
1.
|
In the event the parties wish to go forward with the manufacture and distribution of Flux ESS for NMHG Products such will require:
|
a)
|
A successful performance demonstration which means meeting or exceeding existing lead acid battery performance under a full rage of NMHG Products in various working environments. This is to be demonstrated through the testing of Flux ESS for NMHG Products prototypes. The Parties understand that the requirement defined herein are designed to describe attributes only and may not fully represent all of NMHG’s customer expectations; and
|
b)
|
Viable economic performance, to include initial Flux ESS product costs and total operational costs. Saving must be compelling enough to entice current NMHG customers that use lead-acid batteries to change to the Flux ESS for NMHG Products. The January 2012 economic performance point requires a cost less than or equal to $[***] per W-hr for the Flux ESS based on the volume of [***] packs per year at a consistent cell specification. NMHG shall either confirm or update the economic performance point on a 6-month schedule.
|
c)
|
Mutual approval of an NMHG Master Supply Agreement (“MSA”), which both parties agree to negotiate in good faith.
|
d)
|
e)
|
Upon moving forward with manufacture and distribution of Flux ESS for NMHG Products, NMHG will:
|
f)
|
offer validated Flux ESS for exclusive non lead-acid energy source sale throughout NMHG’s global dealer distribution network thorough June 2016; and
|
g)
|
Provide product introduction / order readiness to NMHG dealers NLT December, 2012
|
Reference Material
|
[1]
|
SOW Jan 2012.doc, NMHG, Ref: NA, Version: NA, Dated: NA
|
[2]
|
Scope_Draft_01192012, Flux Power, Ref: NA, Version: NA, Dated: NA
|
[3]
|
Non-Disclosure Agreement, Flux Power, Ref: NA, Version: NA, Dated December 1, 2011
|
Acronyms
|
Term
|
Definition
|
ARO
|
After Receipt of Order.
|
BCM
|
Battery Control Module
|
BMSM
|
Battery Management System Module
|
CAN
|
Controller Area Network
|
Flux ESS
|
Flux’s Energy Storage System
|
NMHG
|
NACCO Material Handling Group
|
Deliverables Description
|
Project Background
|
Flux Power Services Project Description
|
Contact Information
|
Name
|
Title
|
Phone
|
Email
|
Ed Munar
|
VP Business Development
|
877-505-3589
|
ed@fluxpwr.com
|
Alex Smith
|
Senior Applications Engineer
|
877-505-3589 ext 107
|
alex@fluxpwr.com
|
Brian Gallagher
|
Project Manager
|
877-505-3589
|
brian@fluxpwr.com
|
Laurence Dunn
|
Chief Engineer
|
503-721-6244
|
laurence.dunn@nmhg.com
|
Mark Stonick
|
Global Strategic Technology Procurement
|
503-721-6149
|
mark.stonick@nmhg.com
|
Roger Penfound
|
Project Manager
|
503-721-6884
|
roger.penfound@nmhg.com
|
Location of Work Facilities
|
NMHG Facilities
|
NACCO Material Handling Group, Inc.
|
|||
Address
|
4000 N.E. Blue Lake Road
|
||
City
|
Fairview
|
State/Province
|
OR
|
Country
|
USA
|
Postal Code
|
97024-8710
|
Telephone
|
503-721-6205
|
||
Fax
|
503-721-6200
|
Flux Power Facilities
|
Flux Power, Inc.
|
|||
Address
|
2240 Auto Park Way
|
||
City
|
Escondido
|
State/Province
|
CA
|
Country
|
USA
|
Postal Code
|
92029
|
Telephone
|
877-505-3589 (FLUX)
|
||
Fax
|
760-741-3535
|
Statement of Work
|
System Overview
|
Energy Storage System (ESS)
|
1.
|
Lithium Battery Cells – [***] battery cells with cell voltage ranges from [***] minimum, [***] nominal and [***] maximum.
|
2.
|
Battery Balancing Boards – Monitors voltage and temperature measurements up to 4 battery cells and performs charge balancing.
|
3.
|
Battery Control Module – Centralize controller for managing and monitoring the ESS’s batteries and controls the charging and system level interfaces.
|
4.
|
Battery Interconnects - Buss bars and wiring.
|
5.
|
Power Distribution Unit – Contactors, fusing, interlocks and battery protection.
|
6.
|
DC/DC Converter – Provides regulated 12V power source by bucking down the ESS’s high voltage from the batteries. (POC)
|
7.
|
Enclosure – Battery box with fastening/attachments and lid.
|
Work Packages
|
High Level Design
|
Mechanical Design Package
|
·
|
Develop detailed mechanical 2D and 3D drawings into CAD package.
|
·
|
Create detailed Bills of Materials.
|
·
|
Review detailed mechanical designs with NMHG and peers.
|
Electrical / Wiring Design Package
|
·
|
Develop detailed wiring design and enter the design into 2D wiring schematics.
|
·
|
Create detailed Bills of Materials.
|
·
|
Review detailed electronics design with NMHG and peers.
|
Hardware Prototyping Support
|
·
|
Flux will procure components to build engineering prototype electronics and wiring assemblies.
|
·
|
Flux will procure engineering prototype mechanical assemblies for the enclosure from a local quick turn fabrication source or local source provided by NMHG.
|
·
|
Flux will inventory and assembly prototype Flux ESS units and perform functional checkouts.
|
·
|
Flux will provide technician support for troubleshooting and test assistance.
|
Engineering Prototype Verification
|
·
|
Assemble and perform functional checkout of Flux ESS units.
|
·
|
Support software/hardware integration and testing.
|
·
|
Test hardware features against design requirements.
|
·
|
Verify fit of prototype of components in Flux ESS enclosure for installation into NMHG Products.
|
Software development
|
·
|
Establish communication protocols and provide diagnostics.
|
·
|
Unit test all software modules interfacing with BCM.
|
·
|
Update code as issues and defects are uncovered during prototype testing.
|
Acceptance Test
|
·
|
Prepare Acceptance Test Plan.
|
·
|
Prepare Acceptance Test Procedure.
|
·
|
Perform Software integration testing.
|
·
|
Perform Functional testing.
|
·
|
Perform Final acceptance testing.
|
Requirements
|
General Requirements
|
R.1
|
Flux ESS shall be operational in a temperature range of [***] deg C to [***] deg C
|
R.2
|
Flux ESS shall be have a storage temperature range of [***] deg C to [***] deg C
|
R.3
|
Flux ESS shall be designed with best design engineering practices to protect from electrical short circuits with the following devices:
|
·
|
Fuses/circuit breakers/contactors/PTC devices and used where appropriate
|
·
|
Surge and preventative protection from key off load during high discharge currents.
|
R.4
|
Flux ESS prototype units shall be designed with best design engineering practices to comply with the following standards:
|
·
|
Thermal Shock: SAE J1455
|
·
|
Humidity: SAE J1455
|
·
|
Salt Spray: SAE J1455
|
·
|
Dust and Moisture (NMHG is responsible for overall case sealing): IEC IP 66 or 68
|
·
|
Emissions: EN 12895
|
·
|
Susceptibility: EN 12895 [***]
|
·
|
ESD: SAE J1455
|
·
|
Vibration: SAE J1211
|
R.5
|
Flux ESS prototype unit’s case will be powder coated black.
|
R.6
|
Flux ESS prototype units will have the supplied drawings to fabricate a battery case.
|
R.7
|
Flux ESS prototype unit’s BCM will support [***] protocol.
|
R.8
|
Flux ESS prototype unit’s BCM will have a communication’s rate of [***]kbs.
|
R.9
|
Flux ESS prototype unit’s BCM [***]
|
R.10
|
Flux ESS prototype unit’s BCM [***]
|
R.11
|
Flux ESS prototype unit’s communication wiring will be twisted pair and in compliant with SAE J1939.
|
R.12
|
Flux ESS prototype units will utilize battery cables with a minimum size of 4/0
|
R.13
|
Flux ESS prototype units will provide discharge currents up to [***] amps for [***] second durations.
|
R.14
|
Flux ESS prototype unit’s communications connector will be a [***] device as defined in Figure 1.
|
R.15
|
Flux ESS prototype unit’s internal wiring will use [***]
|
R.16
|
Flux ESS prototype unit’s batteries will be capable of minimum charge rate of [***]
|
Assumptions
|
Ref.
|
Assumption
|
A.1
|
NMHG will assume responsibility of securing [***]
|
A.2
|
NMHG will assume responsibility [***]
|
A.3
|
Flux will source lithium-ion battery cells and select preferred source.
|
A.4
|
Flux will design and implement battery cell mounting and fastening schemes into Flux ESS prototype units.
|
Flux Power Standard Product
|
Deliverables
|
Flux Deliverables
|
Documentation Deliverables
|
Ref.
|
Description
|
Type
|
Format
|
Media
|
|
Mechanical Hardware Design
|
|||||
D.1
|
Top Level Block Diagram
|
—
|
PDF or Visio
|
FTP/email
|
|
D.2
|
CAD Solid Models
|
—
|
.IGS
|
FTP/email
|
|
D.3
|
Bill(s) of Materials
|
—
|
MS Excel
|
FTP/email
|
|
D.4
|
2D Build Prints
|
—
|
PDF
|
FTP/email
|
|
D.5
|
Assembly Instructions
|
—
|
PDF
|
FTP/email
|
|
D.6
|
Engineering Change Orders
|
—
|
PDF or MS Word
|
FTP/email
|
|
Electrical / Wiring Design
|
|||||
D.7
|
Electrical wiring schematics
|
—
|
Visio
|
FTP/email
|
|
D.8
|
Installation Instructions
|
—
|
Text
|
FTP/email
|
|
D.9
|
Power and Communication Interface Document
|
MS Word
|
FTP/email
|
||
D.10
|
Software Build Release Notes
|
—
|
Text
|
FTP/email
|
|
Acceptance Test Plan
|
|||||
D.11
|
Test Plan Document
|
—
|
MS Word or TRACE
|
FTP/email
|
|
D.12
|
Acceptance Test Procedure
|
—
|
PDF or TRACE
|
FTP/email
|
Prototype Hardware Deliverables
|
Ref.
|
Prototype Description
|
Qty Built
|
Qty to NMHG
|
Qty to Flux Power
|
D.13
|
Flux ESS prototype units for NMHG Products
|
3
|
3
|
0
|
|
Project Management
|
|
Planning and Reporting
|
1.
|
Provide the necessary project management support to the project to ensure effective management of the Flux development activities.
|
2.
|
Participate in Flux and NMHG project management meetings.
|
3.
|
Act as the focal point for all issues and problem reports. These problem reports can be informal (via email) but will be used to report and act upon any issue/problem requiring investigation or changes.
|
4.
|
Identify, assess, and prepare contingency or mitigation plans for project risks to reduce or eliminate negative impacts to schedule, cost, and technical execution of the project.
|
5.
|
Provide NMHG with the following reports/plans on a mutually agreed schedule: Status report – includes an executive summary, project progress for reporting period, issues summary, action item summary, project task plans, milestones, deliverables summary, PCR summary.
|
a.
|
Risk report – Risks are tracked and managed throughout the project. Risk detail and summary reports can be exported as an excel file or PDF.
|
b.
|
Issue Report– Issues are tracked and managed through Trace and can be accessed on line. Issue detail and summary reports can be exported as an excel file or PDF.
|
c.
|
Action Items Report – Action items are tracked and managed through Trace and can be accessed on line. Action items detail and summary reports can be exported as an excel file or PDF.
|
d.
|
Schedule Report – Project schedule is tracked using Microsoft Project and schedule report is issued as a PDF file.
|
e.
|
PCR (as required).
|
Estimated Major Events of Project
|
Ref.
|
Project Major Events
|
Estimated Completion
|
Elapsed Time
|
M.1
|
Project Start
|
Receipt of Order*
|
0 Week
|
M.2
|
Flux ESS prototype requirements frozen
|
2 Weeks after M.1
|
2 Weeks
|
M.3
|
NMHG approves design Flux ESS units mechanical enclosures and design review complete
|
2 Weeks after M.1
|
2 Weeks
|
M.4
|
NMHG approves design Flux ESS units electrical and wiring and design review complete
|
2 Weeks after M.1
|
2 Weeks
|
M.5
|
Flux ESS design document review completed and design released
|
1 Week after M.2
|
3 Weeks
|
M.6
|
Flux ESS materials and parts ordered
|
1 Week after M.5
|
4 Weeks
|
M.7
|
Flux ESS material request date (MRD)
|
3 Weeks after M.6
|
7 Weeks
|
M.8
|
Flux ESS prototypes assembled and tested
|
2 Weeks after M.7
|
9 Weeks
|
M.9
|
Flux ESS prototypes shipped to NMHG
|
1 Week after M.8
|
10 Weeks
|
Schedule Fees and Payment Terms
|
Fixed Price
|
Estimated Professional Services Fees
|
Type of Engineering Resource
|
Estimated Hours
|
Standard Hourly Rate
|
Fees
|
|
Project Manager
|
[***]
|
[***]
|
$
|
[***]
|
Senior Mechanical Engineer
|
[***]
|
[***]
|
$
|
[***]
|
Mechanical CAD Designer
|
[***]
|
[***]
|
$
|
[***]
|
Senior Electrical Engineer
|
[***]
|
[***]
|
$
|
[***]
|
Embedded Engineer
|
[***]
|
[***]
|
$
|
[***]
|
Systems Integration Engineer
|
[***]
|
[***]
|
$
|
[***]
|
Total Engineering Estimate
|
$
|
64,000
|
Estimated Prototype and Materials Fees
|
Type of Prototyping Charge
|
Estimated Hours
|
Estimated Fees
|
|
Components
|
$
|
[***]
|
|
Assembly
|
$
|
[***]
|
|
Other
|
$
|
[***]
|
|
Total Prototype and Materials Fee Per Unit
|
$
|
18,320
|
Travel Costs
|
Start Payment and Invoicing
|
Summary of Total Costs
|
Fee Category
|
Total
|
|
Professional Services ($64,000 with a 20% discount)
|
$
|
51,200
|
Prototype and Materials Services (Estimated Fees for 3 units at $18,320)
|
$
|
54,960
|
Project Total
|
$
|
106,160
|
The start payment for the Project is
|
$
|
42,464
|
Date (Milestone)
|
Amount %
|
Start of Project
|
40% of total
|
M.5 - ESS design document review completed and design released
|
30% of total
|
M.9 - ESS prototypes shipped to customer
|
Remainder of total balance due
|
Flux Power, Inc.
|
NACCO Materials Handling Group, Inc.
|
By:/s/ Craig Miller
|
By: /s/ Rajiv K. Prasad
|
Name:Craig Miller
|
Name: Rajiv K. Prasad
|
Title:VP, Director of Legal Affairs
|
Title: VP Global Product Development
|
Date: 2-20-2-12
|
Date: Feb 22, 2012
|